HydraWell Intervention AS

|
Report No.
|
1564 |
|
Type of audit
|
External Audits |
|
Auditee/Customer
|
HydraWell Intervention AS |
|
Date
|
2021/03/16 |
|
Findings
|
9 |
|
Status
|
Closed |
HydraWell Intervention’s deliveries to Oselvar PP&A
Summary
The verification was held in a good atmosphere, the HydraWell participants were very open and willing
to explain and share information.
Our general impression is that HydraWell will strengthen the deliveries for the DNO operations,
especially the spare part philosophy. The online check lists and the overall Management System stands out as robust.
Findings
-
The ODB system does not clearly show high potential events (observations and near misses) with colour code.
HydraWell should evaluate to implement a colour code system to better understand and act according to risk potential.Received-Ok
-
The audit program for 2021 did not include
verification of suppliers.
It is recommended that HydraWell update and
complete the program with applicable information.Received-OK
-
The ODB Checklist does not include a verification tick off field where the onshore supervisor can monitor and review the progress and quality of the contents.
HydraWell to consider implementing a “tick-off-box/field” so that onshore personnel can easily check the quality of the offshore work and that offshore personnel are working according to plan.Received-OK
-
N/A
With regards to the Dovre certification and follow up of B-vendors – HydraWell please submit
a follow-up planPlan received- Ok
-
N/A
To be discussed/evaluated: CFD modelling to be conducted for OBM operations
CFD modelling will be performed
-
N/A
Secure that DNO’s Covid-19 recommendations are implemented in the ODB
Reply received
-
N/A
Ensure that TCP engineer to be involved in project as soon as possible
Dedicated coordinator from Halliburton included in the project
-
N/A
Sende PWC depth intervals to HydraWell (Øystein)
Submitted 24.03.21
-
N/A
Send verification presentations
Received- Ok
Additional Documentation
New Audit Report
\n
HydraWell Intervention AS

|
Report No.
|
1564 |
|
Type of audit
|
External Audits |
|
Auditee/Customer
|
HydraWell Intervention AS |
|
Date
|
2021/03/16 |
|
Findings
|
9 |
|
Status
|
Closed |
HydraWell Intervention’s deliveries to Oselvar PP&A
Summary
The verification was held in a good atmosphere, the HydraWell participants were very open and willing
to explain and share information.
Our general impression is that HydraWell will strengthen the deliveries for the DNO operations,
especially the spare part philosophy. The online check lists and the overall Management System stands out as robust.
Findings
-
The ODB system does not clearly show high potential events (observations and near misses) with colour code.
HydraWell should evaluate to implement a colour code system to better understand and act according to risk potential.Received-Ok
-
The audit program for 2021 did not include
verification of suppliers.
It is recommended that HydraWell update and
complete the program with applicable information.Received-OK
-
The ODB Checklist does not include a verification tick off field where the onshore supervisor can monitor and review the progress and quality of the contents.
HydraWell to consider implementing a “tick-off-box/field” so that onshore personnel can easily check the quality of the offshore work and that offshore personnel are working according to plan.Received-OK
-
N/A
With regards to the Dovre certification and follow up of B-vendors – HydraWell please submit
a follow-up planPlan received- Ok
-
N/A
To be discussed/evaluated: CFD modelling to be conducted for OBM operations
CFD modelling will be performed
-
N/A
Secure that DNO’s Covid-19 recommendations are implemented in the ODB
Reply received
-
N/A
Ensure that TCP engineer to be involved in project as soon as possible
Dedicated coordinator from Halliburton included in the project
-
N/A
Sende PWC depth intervals to HydraWell (Øystein)
Submitted 24.03.21
-
N/A
Send verification presentations
Received- Ok
Additional Documentation